5T MRI: Bridging innovation and whole-body clinical need

Authors

  • Lan Zhang, M.D. The 1st Affiliated Hospital of Henan University of Chinese Medicine, Henan, People’s Republic of China.

DOI:

https://doi.org/10.46475/asean-jr.v26i2.950

Keywords:

Abdominal, Cardiac, MRI, TOF, Ultra-high-field MRI, 5.0T MRI.

Abstract

This article introduces the clinical debut of whole-body 5T magnetic resonance imaging (MRI), a novel ultra-high-field system designed to bridge the gap between conventional 3T and 7T MRI. Developed through international collaboration, the 5T platform overcomes major technical barriers in RF design, field homogeneity, and SAR control, to enable stable, high-resolution imaging across the whole body. Clinical evidence demonstrates its superiority in multiple applications, including intracranial vascular imaging, cardiac and coronary assessment, and abdominal imaging. By delivering both ultra-high resolution and whole-body capability, 5T MRI establishes a new paradigm for clinical imaging and paves the way for broader access to advanced diagnostic technologies.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

U.S. Food and Drug Administration [Internet]. Silver Spring (MD): The Administration; October 12, 2017 [cited 2025 Apr 28].. FDA clears first 7T magnetic resonance imaging device. Available from:

https://www.fda.gov/news-events/press-announcements/fda-clears-first-7t-magnetic-resonance-imaging-device

Shi Z, Zhao X, Zhu, S, Miao, X, Zhang Y, Han S, et al. Time-of-flight intracranial MRA at 3 T versus 5 T versus 7 T: Visualization of distal small cerebral arteries. Radiology 2023;306:207–17. doi: 10.1148/radiol.220114.

Lu H, Miao X, Wang D, Zheng X, Zhang S, Wang R, et al. Feasibility and clinical application of 5-T noncontrast dixon whole-heart coronary MR angiography: A prospective study. Radiology 2024;313: e240389. doi: 10.1148/radiol.240389.

Guo Y, Lin L, Zhao S, Sun G, Chen Y, Xue K, et al. Myocardial fibrosis assessment at 3-T versus 5-T myocardial late gadolinium enhancement MRI: Early results. Radiology 2024;313:e233424. doi: 10.1148/radiol.233424.

Zheng L, Yang C, Liang L, Rao S, Dai Y, Zeng M. T2-weighted MRI and reduced-FOV diffusion-weighted imaging of the human pancreas at 5 T: A comparison study with 3 T. Med Phys 2023;50:344–53. doi: 10.1002/mp.15970.

Zheng L, Yang C, Sheng R, Dai Y, Zeng M. Renal imaging at 5 T versus 3 T: a comparison study. Insights Imaging 2022;13:155. doi: 10.1186/s13244-022-01290-9.