VALIDATION OF EJECTION FRACTION OBTAINED FROM GATED SPECT IMAGING USING NCAT PHANTOM
Keywords:
Ejection Fraction, Gated SPECT, NCAT phantom, Monte Carlo SimulationDownloads
Metrics
References
Garcia EV, Santana C, Faber TL, Cooke DI. Methods for evaluating left ventricular function computed from ECG-Gated myocardial perfusion SPECT [document on the Internet]. 2nd virtual congress of cardiology; [cited 2007 Aug 9]. Available from: http://www.fac.org.ar/seve/llave/image/garcia/garciai.htm.
Paul AK, Nabi HA. Gated myocardial perfusion SPECT: basic principles, technical aspects, and clinical applications. J Nucl Med Technol 2004; 32: 179-187.
Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, Van Train KF, Berman DS. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995; 36(11): 2138-2147.
Go V, Bhatt MR, Hendel R. The diagnostic and prognostic value of ECG-Gated SPECT myocardial perfusion imaging. J Nucl Med 2004; 45: 912-921.
Nichols K, Santana CA, Folks R, Krawezynska E, Cooke CD, Faber TL et al. Comparison between ECTb and QGS for assessment of left ventricular function from gated myocardial perfusion SPECT. J Nucl Cardiol 2002; 9: 285-293.
Segars WP. Medical imaging simulation techniques and computer phantoms [Homepage on the internet]. Department of Radiology Johns Hopkins University. Available from: http://dmip.rad.jhmi.edu/people/faculty/Paul.
Feng B, Sitek A, Gullberg GT. Calculation of the left ventricular ejection fraction without edge detection: Application to small hearts. J Nucl Med 2002: 43: 786-794
University ofWashington. SimSET homepage [Homepage on the internet]. 1999 [updated 2006 Jan 19: cited 2007 Dec 3]. Available from: http://depts.washington.edu/~simset/htm//simset_main.html.
Faber TL, Cooke CD, Peifer JW, Pettigrew RI, Vansant JP. Leyendecker JR, et al. ThreeDimensional displays of left ventricular epicardial surface from standard cardiac SPECT perfusion quantification techniques. J Nucl Med. 1995; 36: 697-703.
Cooke CD, Garcia EV, Cullom Si, et al. Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: a simulation study based on canine and patient data. J Nucl Med. 1994; 35: 1185-1192.
The INVIA, LLC and the Regent of the University of Michigan. Reference manual for 4D-MSPECT v.4.2: comprehensive and flexible software for quantitative assessments of cardiac function and perfusion using emission tomography. 2006.
Shaefer WM, Lipke C, Standke D, Kuhl HP. Nowak B, Kaiser H, et al. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Toolbox with QGS and 4D-MSPECT. J Nucl Med 2005; 46:1256-63.
Nakajima K, Higuchi T, Yaki J, Kawano M. Tonami N. Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs. J Nucl Med 2001; 42: 1571-78.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 The ASEAN Journal of Radiology
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Disclosure Forms and Copyright Agreements
All authors listed on the manuscript must complete both the electronic copyright agreement. (in the case of acceptance)