VALIDATION OF EJECTION FRACTION OBTAINED FROM GATED SPECT IMAGING USING NCAT PHANTOM

Authors

  • Soontaree SRIWONGTA Department of Radiological Technology, Faculty of Medical Technology, Mahidol University
  • Chiraporn TOCHAROENCHAL Department of Radiological Technology, Faculty of Medical Technology, Mahidol University
  • Pawana PUSUWAN Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University

Keywords:

Ejection Fraction, Gated SPECT, NCAT phantom, Monte Carlo Simulation

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

Garcia EV, Santana C, Faber TL, Cooke DI. Methods for evaluating left ventricular function computed from ECG-Gated myocardial perfusion SPECT [document on the Internet]. 2nd virtual congress of cardiology; [cited 2007 Aug 9]. Available from: http://www.fac.org.ar/seve/llave/image/garcia/garciai.htm.

Paul AK, Nabi HA. Gated myocardial perfusion SPECT: basic principles, technical aspects, and clinical applications. J Nucl Med Technol 2004; 32: 179-187.

Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, Van Train KF, Berman DS. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995; 36(11): 2138-2147.

Go V, Bhatt MR, Hendel R. The diagnostic and prognostic value of ECG-Gated SPECT myocardial perfusion imaging. J Nucl Med 2004; 45: 912-921.

Nichols K, Santana CA, Folks R, Krawezynska E, Cooke CD, Faber TL et al. Comparison between ECTb and QGS for assessment of left ventricular function from gated myocardial perfusion SPECT. J Nucl Cardiol 2002; 9: 285-293.

Segars WP. Medical imaging simulation techniques and computer phantoms [Homepage on the internet]. Department of Radiology Johns Hopkins University. Available from: http://dmip.rad.jhmi.edu/people/faculty/Paul.

Feng B, Sitek A, Gullberg GT. Calculation of the left ventricular ejection fraction without edge detection: Application to small hearts. J Nucl Med 2002: 43: 786-794

University ofWashington. SimSET homepage [Homepage on the internet]. 1999 [updated 2006 Jan 19: cited 2007 Dec 3]. Available from: http://depts.washington.edu/~simset/htm//simset_main.html.

Faber TL, Cooke CD, Peifer JW, Pettigrew RI, Vansant JP. Leyendecker JR, et al. ThreeDimensional displays of left ventricular epicardial surface from standard cardiac SPECT perfusion quantification techniques. J Nucl Med. 1995; 36: 697-703.

Cooke CD, Garcia EV, Cullom Si, et al. Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: a simulation study based on canine and patient data. J Nucl Med. 1994; 35: 1185-1192.

The INVIA, LLC and the Regent of the University of Michigan. Reference manual for 4D-MSPECT v.4.2: comprehensive and flexible software for quantitative assessments of cardiac function and perfusion using emission tomography. 2006.

Shaefer WM, Lipke C, Standke D, Kuhl HP. Nowak B, Kaiser H, et al. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Toolbox with QGS and 4D-MSPECT. J Nucl Med 2005; 46:1256-63.

Nakajima K, Higuchi T, Yaki J, Kawano M. Tonami N. Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs. J Nucl Med 2001; 42: 1571-78.

Downloads

Published

2023-04-27

How to Cite

1.
SRIWONGTA S, TOCHAROENCHAL C, PUSUWAN P. VALIDATION OF EJECTION FRACTION OBTAINED FROM GATED SPECT IMAGING USING NCAT PHANTOM. ASEAN J Radiol [Internet]. 2023 Apr. 27 [cited 2024 Dec. 11];14(2):119-26. Available from: https://www.asean-journal-radiology.org/index.php/ajr/article/view/824

Issue

Section

Original Article

Most read articles by the same author(s)

Similar Articles

1 2 3 4 > >> 